How to add a Ganymede Integrated Scale for use in Weigh and Dispense to a procedure
  • 08 Nov 2022
  • 2 読む分

How to add a Ganymede Integrated Scale for use in Weigh and Dispense to a procedure


The content is currently unavailable in Ja - 日本語. You are viewing the default English version.
記事の要約

Follow the steps below to learn how to add a Ganymede Integrated Scale for use in Weigh and Dispense while authoring a procedure.

NOTE:

The Dispense Action requires a material to be added as a resource input on the procedure. The below steps only detail steps for configuring a procedure with the Ganymede integrated scales.

Step 1
Navigate to 'Tempo' then click Procedures.

Step 2
Click Templates under the Procedure menu.

Step 3
Click Create new procedure template in the upper right corner of the UI. A Popup for 'Create New Procedure Template' will display.

Step 4
Enter a 'Title', select Standard Operating Procedure and click 'Next'. The 'Create new procedure template' popup will transition to 'Author Information'.

Step 5
Make all users, a team, or a specific user, an author of this procedure, then click Next. The 'Create New Procedure Template' Popup will transition to 'SOURCE DOCUMENT'.

Step 6
Select the No, I don't have a source document option or choose a local file from your computer or a PDF from your DMS, if applicable, then click Create.

Step 7
If using a source document, highlight a step in your document displayed on the left and click the New Step icon. If not using a source document, click Add step in the bottom middle of the UI. A step will be created.

Step 8
Under the 'Inputs' section in the sidebar, click Add new input and select 'Resource'. The sidebar will transition to the 'Input: Add Resource' screen.

Step 9
Enter a Name / Prompt.

Step 10
Select Equipment under 'Resource Type'.

Step 11
Select 'Resource Query' from the Scan Type dropdown.

Step 12
Optionally, select an option from the Condition dropdown.

Step 13
Click Add resource.

Step 14
Under the 'Actions' section in the sidebar, click Add new action and select 'Dispense'.

Step 15
Enter the applicable information for the required fields:

FieldDescription
PromptOperator prompt
Pull source material from...Material resource input specified in the procedure
Target sublot number formatGives the operator a format to follow when entering sublot number
Dispensing modeThe dispense mode, manual or weighing
Weighing modeThe weighing mode type, positive, negative, residual, or layered
Target quantity typeThe target quantity type, manually set by author or referenced process parameter
Pull equipment from...Available if Dispensing mode is Weighing for use with integrated scales
NOTE:

Ganymede integrated scales are supported when the Dispensing mode is set to Weighing and Weighing mode is set to Positive for Tempo 6.5.

Step 16
Select an option under 'Automatically allocate dispensed sublot to batch run?' When set to “yes” the material that is dispensed during this action will be allocated to the batch run the procedure run is in.

Step 17
Select an option under 'Required to print a label'.

Step 18
Click Add Action.


Changing your password will log you out immediately. Use the new password to log back in.
First name must have atleast 2 characters. Numbers and special characters are not allowed.
Last name must have atleast 1 characters. Numbers and special characters are not allowed.
Enter a valid email
Enter a valid password
Your profile has been successfully updated.