Step 1
On Mobile, navigate to Procedures and search for the name of a procedure configured with a Ganymede for weigh and dispense.
Step 2
Scan a material resource code (that has compatible UOM for weigh and dispense) and scan the QR code of an equipment instance configured for use with the Ganymede integration.
Step 3
Tap on 'Dispense' Action and tap 'Record Weight'.
Step 4
Zero the scale and then place the dispensing container on the scale.
Step 5
Tap 'Tare and begin' in the upper right of the popup window to begin the weigh and dispense action. This will send a 'tare' command to the scale and start publishing the real-time scale weigh value.
Step 6
Begin dispensing material into the container on the scale until the 'Target weight' is reached.
Step 7
Click 'Save' in the upper right of the 'Weigh Material' window, enter a name for the dispensed sublot and tap 'Dispense sublot'. Enter your PIN to verify and save the dispensed weight value.
Step 8
Print a label for the dispensed container and tap 'Done' in the upper right of the UI.
Step 9
Tap on the 'Check Button' in the bottom Right of the UI to Complete the Step.